GERHARDT SOXTHERM PDF

sure to read also the instruction manual for the Soxtherm Manager SX PC! Observe On the basis of the C. Gerhardt conditions of warranty our products are. Gerhardt. Soxtherm – Automatic Rapid Extraction Systems. Modern Laboratory Management. dt has been known for dacades for manufac-. A rapid extraction system which runs fully automatically and can be operated without supervision with confidence. It provides an efficient high performance.

Author: Telmaran Faera
Country: Costa Rica
Language: English (Spanish)
Genre: Video
Published (Last): 19 March 2016
Pages: 306
PDF File Size: 3.80 Mb
ePub File Size: 13.33 Mb
ISBN: 470-9-80642-619-5
Downloads: 62156
Price: Free* [*Free Regsitration Required]
Uploader: Shaktilar

The data obtained can then be used to make fast environmental decisions. Illuminated extraction beakers allows operator check the extraction process visually constantly.

Concept Gerhardt has been offering fully automatic systems under the brand name Soxtherm. Depending on the size of the laboratory and the sample throughput, the customer now has the option of a 2, 4, or 6 place system.

The Soxhlet extraction is a frequently used method to analyze certain fibers and additives Gerhardt supply several systems for Soxhlet extraction and acid hydrolysis, fully automated Soxtherm and Hydrotherm or traditional heating systems. Thanks to the close relationship with our customers and partners worldwide, this highly successful instrument has been improved further.

Extraction of coatings and finishes in textiles.

Extremely versatile – fat extraction or sample preparation. Traditional Soxhlet extraction systems EV 6 are supplied with either a 4 or 6 place hotplate, top moulds, air bath inserts and condenser supports.

The solvent is re-circulated to rinse the extractable material into the bottom of the beaker. Hydrotherm Acid Hydrolysis Systems Traditional methods involve the digestion of food and feed with strong Hydrochloric acid, in beakers on a hotplate, in order to digest the protein and to free the bound lipids.

High gerhradt operational safety Separate plug-in limit temperature connectors. Front window pane made of safety glass. The fully automated process ensures highest precision for minimum input. Gerhadt, is up to four times faster than the conventional Soxhlet extraction method. Just insert the extraction beaker and let it run: It provides an efficient high performance.

Gerhardt Soxtherm Oilseed Extractor — Northern Crops Institute

They automate recurring analysis processes in accordance with national and international standards and norms. The models can be used gerhafdt in any desired combination. The device runs fully automatically and can be operated without supervision with confidence. The European Commission has put on hold plans to increase maximum authorised mercury level in fish. Its gerhsrdt areas of application are fat determination of foods and feed stuffs, and preparation of samples for residue analysis and environmental analysis.

Traditional methods involve the digestion of food and feed with strong Hydrochloric acid, in beakers on a hotplate, in order to digest the protein and to free the bound lipids. The controller, Multistat, can control and monitor up to 4 units individually. The device runs fully automatically and can be operated without supervision with confidence.

Temperature, compressed air, cooling water and the filling levels of solvent tanks are monitored automatically. We are pleased to help: The time your presence is required is reduced to a minimum. One control unit monitor and control up to 4 extraction units.

A rapid extraction system which runs fully automatically and can be operated without supervision with confidence. Related Searches Electronic control unit Analyzer for the food industry Nitrogen analyzer Gerhardt laboratory digester Carbon analyzer Chlorine analyzer COD digester Thermo-mixer Digital thermo-mixer Gerhardt distillation system Bench-top thermo-mixer Gerhardt automatic gerharvt system Analog heating plate Laboratory thermo-mixer Gerhardt steam distillation system Laboratory dryer Glassware dryer Hydrolysis unit Protein analyzer Laboratory extractor.

Gerhardt products are quality products for daily routine sodtherm in the laboratory.

Extraction – Soxtherm – Gerhardt Malaysia

Many companies in the textile industry either have their own test laboratory to check the quality and characteristics of their raw materials and final products or have them soxtgerm tested by research institutes. The solvent used can be almost entirely recovered.

Open the catalog to page 2. Economical and fast Solvents can be reclaimed. The control software monitors and logs all processing and device data.

Faster than conventional Soxhlet method. See the complete list of deadlines! The Gerhardt Soxtherm automates and speeds the extraction process and can evaporate and recover the solvent. Features Series extraction Easy to upgrade the system.

It delivers precise extraction results of the highest validity. Extremely versatile Used of many areas of analysis, such as fat content determination in food and feed, preparation of samples in residue and environmental analysis.

Possible samples weights depend on the size of the available thimbles. Available as two, four or six place systems, up to four units can be operated independently with software or a single programmable controller. After digestion the sample is filtered, washed, dried then extracted by Soxhlet.

The Gerhardt Hydrotherm fully automates this process whilst still conforming to international standards of analysis.

Rapid extraction system for solid-liquid extractions

Soxhlet glass components can be ordered separately. Soxtherm is controlled by either a Multistat controller or Soxtherm Manager software.

Gerhardt are highly developed special equipment.