Friends of PDF

all our visitors are our friends. we love them all. we want them to find and download pdf files from our website. we do our best to satisfy them. and they share our website on their facebook walls.




ASTM D3330 PDF

31 Jan ASTM D describes six methods used to test the adhesion strength of pressure sensitive tape. Learn how to test pressure sensitive adhesive tapes to ASTM D with the best equipment. “These test methods are under the jurisdiction of ASTM Committee D on. Packaging published as D – 76 Last previous cdition D/DM –

Author: Shaktishicage Mazuzilkree
Country: Anguilla
Language: English (Spanish)
Genre: Video
Published (Last): 6 April 2007
Pages: 175
PDF File Size: 19.86 Mb
ePub File Size: 14.23 Mb
ISBN: 400-8-84717-559-7
Downloads: 32740
Price: Free* [*Free Regsitration Required]
Uploader: Kajijin

ASTM D3330 Peel Adhesion of Pressure Sensitive Tape How to Guide

The liner is peeled from the adhesive in the same manner as in astm d3330 a single-coated tape from a standard panel. This test also measures peel adhesion with a degree peel.

The 25mm wide jaws are better for aligning smaller sample sizes. The values stated in each system may not be exact equivalents, therefore, each system must be used independently without combining astm d3330 in any way. Pressure sensitive tape is used in a variety e3330 applications including duct tape, electrical tape, masking tape, packaging, double-sided tape, bandages, medical devices, and other uses.

Now apply a strip of the tape to a rigid panel, such as the standard stainless steel panel. Adtm steps of Test Method A. Substitution of representative samples of materials in question for the standard steel panel would suffice to do this. Historical Version s – view previous versions of standard. ASTM D Astm d3330 Method D provides a means of assessing the astm d3330 of the adhesion of a given aetm of pressure-sensitive adhesive tape.

ASTM D Method F measures the adherence of single-coated tapes to a standard steel panel or your chosen astm d3330 when peeled at a 90 degree angle.

ASTM D includes six different methods for testing the peel adhesion strength of pressure sensitive tape. Remove a mm specimen of the tape to be tested. We are confident that we have astm d3330 you are looking for.

These test methods may not provide design information as there is usually no direct relationship between peel astm d3330 and any functional requirement.

We offer machines, apparatus, testers, tensile grips, test fixtures, clamps, holders, jigs, faces, jaws, extensometers, environmental and humidity chambers, furnaces, baths and custom solutions dd3330 unique applications. Testing is then d333 for degree peel adhesion. If the adherent is set on an angle, astm d3330 will cause an error. The tape is applied to the substrate with an even pressure using a handheld roller. This unique standard consists of Methods A through F, identifying ways to measure peel adhesion with degree and 90 degree peel methods.

The information below should help you astm d3330 the basic test procedures and the equipment required to meet this standard with accuracy. Other sample widths available upon request Effective and simple to use Blade replacement takes mere seconds. Although we can provide astm d3330 with guidance, we recommend you purchase and closely follow the ASTM International testing standard. The D3330 are small and astm d3330, perfect for very small load cells testing at low loads.

Repeat steps 1 to 6 of Test Method A. This is because the measured peel force is not astmm for a astm d3330 area of stress. Test Method D can show the amount of force astm d3330 to remove a liner that covers the adhesive side of a tape at a specified peel rate.

ASTM D Tape Adhesion Strength Testing – ADMET

Rated to 1 kN lbf Maximum specimen thicknesses from 10 mm to 50 mm 0. The tape is astm d3330 from astm d3330 panel at 90 degree zstm at a constant speed, during which time the force required to effect peel is measured. The test materials consist of preparing several strips of tape to be tested and a hard substrate, such as a metal plate.

When testing face side adhesion, the double-coated tape is adhered to a stainless steel panel or your chosen substrateliner r3330 up.

V3330 purpose of ASTM D data results astm d3330 assess the uniformity of adhesion for pressure sensitive tapes. This software enables you to easily astm d3330 average peel force over a chosen displacement. GK Mechanical Vice Grip. This plot will be an important aspect of data retrieval and therefore we highly recommend our XyPlot software.

The peel plot you are looking for will be force vs displacement over the length of the peel line. Given specific pressure-sensitive tape and a aatm in terms of the minimum or maximum peel value expected for this tape, the data from the test can be used in conjunction with acceptance criteria.

The clamping force is all air operated giving more consistent test results, less work for the operator, less room for error, and is quicker qstm easier for testing numerous samples. The astm d3330 is then pulled from the plate astm d3330 a degree angle at a specified rate, and peel adhesion is measured.